BIOGAS COMPRESSORS / RNG GRID INJECTION

UVG315/ VG250

2x UVG 315  

LOCATION: SPAIN
FLUID: Biogas    
POWER INSTALLED:
 400 kW (x2)
INLET PRESSURE: 50 mbar(g)
WORKING PRESSURE: Up to 15 bar(g)
FLOW RATE: 0<1850<3700 Nm³/h
AMBIENT TEMPERATURE: -10/+40°C

VG 250

LOCATION: SPAIN
FLUID: Biomethane  
POWER INSTALLED:
 315 kW
INLET PRESSURE: 50 mbar(g)
WORKING PRESSURE: Up to 22.5 bar(g)
FLOW RATE: 0<530<1045 Nm³/h
AMBIENT TEMPERATURE: -10/+40°C

 

A complete automatic solution for biogas upgrading and biomethane grid injection consisting of:
– Two open frame screw compressors for biogas upgrading installed inside a container (40’) in Spain. Designed in compliance with the European standards for classified Atex zone 2. It is suitable for outdoor installation, water-cooled, outlet gas temperature control, fine filtration and controlled remote by PLC;
– One screw compressor for biomethane grid injection, in compliance with the Spain requirements for the biomethane grid injection. Designed for classified Atex Zone 2 for outdoor installation, water-cooled, outlet gas temperature control, fine filtration, equipped with silencers for reducing the noise level to 75 dB(A) at 1 meter and controlled remote by PLC.

[contact_form]

OTHER REFERENCES

Model UVG 200

USA

Screw biogas compressor for upgrading located in USA. Designed in compliance with north american standards, suitable for outdoor installation, air-cooled, completed with electro-pneumatic by-pass system and controlled by PLC.
View more

UVG 22

France

Screw compressor for CO₂ located in France. Designed for non-hazardous area for outdoor installation. It is air cooled and completed with fine filtration, electrical cabinet in the compressor skid, fully electrical by-pass system and controlled by PLC. The compressor is equipped with silencers (maximum noise level: 74 dB(A) at 1 meter).
View more

UVG 160

USA

Screw biogas compressor for upgrading located in USA. Designed in compliance with ASME and UL standards (Class 1 Division 2) for outdoor installation. It is air cooled and completed with fine filtration, temperature control, electro-pneumatic bypass valve and controlled by PLC.
View more

ADI115-22

Czech Republic

Single stage reciprocating compressor for biomethane installed in Czech Republic. Designed for classified Atex Zone 2 for outdoor installation. It is air cooled and completed with electro-pneumatic by-pass system, fine filtration and controlled by PLC.
View more

ADI115-30

Netherlands

Double stage reciprocating compressor installed in the Netherlands. Designed for classified Atex Zone 2 for outdoor installation. It is water cooled and completed with bleed valve for depressurization to vent, electro-pneumatic proportional bypass valve and controlled by PLC.
View more

UVG 650

Denamrk

Two screw compressors for biogas upgrading installed in Denmark. Each compressor is installed inside a dedicated 40' container. They are designed for classified ATEX Zone 2 for outdoor installation. The compressors are water-cooled and completed with heat recovery, temperature control, electropneumatic by-pass valve and are controlled by PLC.
View more

UVG 18.5

Germany

Screw biogas compressor for upgrading located in Germany. Designed for classified Atex Zone 2 for outdoor installation. It is air cooled and completed with fine filtration, mechanical bypass valve and controlled by HMI.
View more

VG 55

Germany

crew compressor for natural gas located in Germany. Designed for classified Atex Zone 2 for outdoor installation. It is air cooled and completed with fine filtration, electromechanical by-pass system and controlled by PLC.
View more

UVG 355

Italy

Screw compressor for biogas upgrading located in Italy. Designed for outdoor installation. It is water cooled and completed with temperature control, fully electrical by-pass system, fine filtration and controlled by PLC. It is equipped with silencers for reducing the noise level to 75 dB@ 10m.
View more

UVG132/BVG30

Lithuania

Two screw compressors for biogas upgrading located in Lithuania. The first unit supplies the biogas to the upgrading system, the second recirculates the remaining methane and carbon dioxide to obtain greater efficiency for its recovery through the upgrading system. Both compressors are open frame, installed inside container, designed for classificated Atex Zone 2, equipped with with electro-pneumatic by-pass system, fine filtration, temperature control and controlled by PLC.
View more