UVG500-UK

BIOGAS COMPRESSOR UVG500 LOCATION: UKFLUID: BiogasPOWER INSTALLED: 630 kWINLET PRESSURE: 70 mbar(g)WORKING PRESSURE:  12.6-14.7 bar(g)FLOW RATE: 0<1007<2793 Nm³/hAMBIENT TEMPERATURE: -20/+40 °C Screw biogas compressor for upgrading installed in container 20″ equipped with silencers for noise reduction down to 80 dB@1m. Designed for classified Atex Zone 2, suitable for outdoor installation -20/+40°C, completed with heat recovery system and controlled by PLC.

UVG250-Sweden

BIOGAS COMPRESSOR UVG250 LOCATION: SwedenFLUID: BiogasPOWER INSTALLED: 315 kWINLET PRESSURE: 150 mbar(g)WORKING PRESSURE:  16 bar(g)FLOW RATE: 0<1.300 Nm³/hAMBIENT TEMPERATURE: -25/40 °C Screw biogas compressor for upgrading installed in Sweden. Designed for classified Atex Zone 2 for outdoor installation, completed with heat recovery.

UVG132-France

BIOGAS COMPRESSOR UVG132 LOCATION: FranceFLUID: BiogasPOWER INSTALLED: 160 kWINLET PRESSURE: 150 mbar(g)WORKING PRESSURE:  13.6 bar(g)FLOW RATE: 0<680 Nm³/hAMBIENT TEMPERATURE: -10/40 °C Screw biogas compressor for upgrading, installed in anaerobic digestion plant located in France. Designed for classified Atex Zone 2 and outdoor installation, completed with suction filter, heat recovery, by-pass system and control of gas outlet temperature.

BVG160-Italy

BIOGAS COMPRESSOR BVG160 LOCATION: ItalyFLUID: BiogasPOWER INSTALLED: 200 kWINLET PRESSURE: 150-200 mbar(g)WORKING PRESSURE: 8,3 bar(g)FLOW RATE: 0<1125 Nm³/hAMBIENT TEMPERATURE: -20/45°C Screw biogas compressor for upgrading based on PSA technology installed in container 40″ located in Sicily. Designed for classified Atex Zone 2, suitable for outdoor conditions -20/45°C, completed with suction dewatering system and gas treatment system.

UVG160-France

BIOGAS COMPRESSOR UVG160 LOCATION: FRANCEFLUID: BiogasPOWER INSTALLED: 200 kWINLET PRESSURE: 100 mbar(g)WORKING PRESSURE:  16.5 bar(g)FLOW RATE: 0<844 Nm³/hAMBIENT TEMPERATURE: -20/40 °C Screw compressor for biogas upgrading located in France. Designed for outdoor installation, completed with heat recovery, fine filtration and temperature control. It is equipped with silencers (maximum noise level: 80 dB(A) at 1 meter).

UVG250-Denmark

BIOGAS COMPRESSOR UVG250 LOCATION: DenmarkFLUID: BiogasPOWER INSTALLED: 315 kWINLET PRESSURE: 250 mbar(g)WORKING PRESSURE:  16 bar(g)FLOW RATE: 0<1.400 Nm³/hAMBIENT TEMPERATURE: -20/40 °C Screw biogas compressor for upgrading installed in anaerobic digestion plant located in Denmark. Designed for classified Atex Zone 2 for outdoor installation, completed with heat recovery and silencers.

UVG200-France

BIOGAS COMPRESSOR UVG200 LOCATION: FranceFLUID: BiogasPOWER INSTALLED: 250 kWINLET PRESSURE: 150 mbar(g)WORKING PRESSURE:  18/18.5 bar(g)FLOW RATE: 0<825 Nm³/hAMBIENT TEMPERATURE: -10/40 °C Screw biogas compressor for upgrading installed in anaerobic digestion plant located in France. Designed for classified Atex Zone 2 for outdoor installation, completed with suction filter, heat recovery, fine filtration and temperature control.

UVG90-France

BIOGAS COMPRESSOR UVG90 LOCATION: FranceFLUID: BiogasPOWER INSTALLED: 110 kWINLET PRESSURE: 250 mbar(g)WORKING PRESSURE:  16 bar(g)FLOW RATE: 0<490 Nm³/hAMBIENT TEMPERATURE: -20/40 °C Screw biogas compressor for upgrading installed in anaerobic digestion plant located in France. Designed for classified Atex Zone 2 for outdoor installation, completed with heat recovery.

UVG250-Italy

BIOGAS COMPRESSOR UVG250 LOCATION: ItalyFLUID: BiogasPOWER INSTALLED: 315 kWINLET PRESSURE: 250 mbar(g)WORKING PRESSURE:  14 bar(g)FLOW RATE: 0<1.594 Nm³/hAMBIENT TEMPERATURE: -20/40 °C Two screw biogas compressors for upgrading installed into two containers 40 feet in waste water treatment plant located in Italy. The compressors are water cooled with dry cooler installed on the roof of each container. Designed for classified Atex Zone… Continue reading UVG250-Italy

UVG132-France

BIOGAS COMPRESSOR UVG132 LOCATION: Paris, FranceFLUID: BiogasPOWER: 132 kWINLET PRESSURE: 150 mbar(g)WORKING PRESSURE:  15.5 bar(g)FLOW RATE: 0<732 Nm³/hAMBIENT TEMPERATURE: -10/40 °C Screw biogas compressor for upgrading, installed in anaerobic digestion plant located in France. Designed for classified Atex Zone 2 for outdoor installation, completed with heat recovery and silencers.